UD2-102EC

UD2-102EC is a hand-operated ultrasonic flaw-detector “Peleng” series. It makes possible detection and sizing of inner flaws in metallic and non-metallic materials, also in welding. 

UD2-102EC can operate in hard-to-reach places, on big altitude and in hazardous conditions. It provides 100 presets and can save the results.

 

SUPPLY SET:
  • “Railway vehicles” edition
  • “Locomotive” edition
  • “Subway” edition
  • “Acceptance Control” edition
  • "Oil and Gas" edition
  • “Railway Machines” edition
  • “Rail” edition

Data display:

  • A-scan (freeze screen, magnify, envelope)
  • B-scan (ultrasonic cross-section display)
  • W-scan (basic beam tracing display for angle beam probe)

User-friendly interface:

  • digital parameters can be input with digit keys or with “+” and ”-“ keys;
  • most used settings are set by hot keys and their condition is always indicated;
  • constant indication of the sensitivity;
  • essential variables (frequency, beam angle, crystal mode, etc.) are always indicated;
  • procedure number, type of test piece, etc. – are always indicated (for specializes software editions);
  • latest set of variables is automatically saved when the instrument is turned off.

Automatic flaw alarm:

  • two gates, allowing to realize various methods of testing;
  • independent replacement of the begin and the end of the gate, possibility to replace the whole gate;
  • sound and light alarm (alarm can be prolonged in order not to miss short signals from small flaws).

Automatic algorithms:

  • automatic time-base optimisation;
  • sound velocity automatic set in correspondence to the material, wave mode and beam angle;
  • automatic set of pulse repetition frequency;
  • distance meter zero automatic calibration by the reference signal;
  • automatic sensitivity set by the necessary flaw size;
  • automatic flaw sizing by the built-in DGS-curves.

Sensitivity equalisation:

  • manual set time-gain;
  • automatic time gain;
  • built-in DAC;
  • manual DAC;
  • automatic time-gain, based on built-it DGS (has no analogs!).
 

Flaw sizing:

  • constant indication of cordinates, equivalent size, detection coeffitient, and amplitude by “smart” mark, tracking the pulse maximum;
  • “manual” mark for measuring any pulse parameters (in A-scan and B-scan, also in “frozen” screen) with automatic maximum tracking.
Nonvolatile memory:
 
  • saves A-scans, B-scans and work reports;
  • creates and saves custom presets, protected from change with passwords;
  • creates and saves “sets of presets” for multi-stage testing (has no analogs!);
  • all data can be transferred to PC.
 

 

Technical data

 

 Ultrasonic methods pulse-echo
pitch-catch
backwall-echo  
 Eddy-current methods phase
amplitude
 Eddy-current mode

dynamic

static

 Ultrasonic channels 1
 Eddy-current channels 1
 Main indicator

electroluminescent

 Secondary indicator sound alarm
LED indicator
LED on the eddy-current probe
 Frequency, MHz

          Edition Acceptance Control

1,25;  1,8;  2,5;  5,0

            Edition “Locomotive”; “Railway vehicles”; “Subway”

0,4;  1,25;  2,5;  5,0

          Edition Rail”

2,5

 Pulser amplitude, V
          high 120
          low 4,5
 Pulse repetition frequency, Hz 25 ... 5000
          Ultrasonic scans А‑scan
W-scan
В-scan
          Eddy-current scans

“running” scan

 Ultrasonic gain range, dB 0 ... 80
 Eddy-current gain range, times 0 ... 63
 Thickness indication step, mm 0,01
 Time-gain range, dB    60
 Eddy-current frequency, kHz 10 ... 100
 Eddy-current generator voltage, V 0,8;  1,5;  3,4;  8,3
 Flaw depth range (in steel), mm 1 … 8850
 Time base range, µs 6 … 3048
 Measured crack height, mm 0,1 … 9,9
 Measured thickness range (steel), mm 3 ... 5000
 Working temperature range, °C -20 … +50
 Weight, kg 1,2
 Dimentions, mm 140x220x42